Connection for START S6BL with safety edge

Published the 19.02.2021

START-S6BL " safety edge" contact update

Attention: new connection for the safety edge on START S6BL:
DIP8B in ON and open JUMPER: safety edge not activated
DIP8B in OFF and OPEN jumper: activated safety edge ( normally closed contact)
DIP8B in OFF and CLOSED jumper: activated 8K2 ( contact for resistive edge)

Connection of the ALT command on terminals 33-34: stop the gate and renverse for 1,5sec.
If LED L1 flashes and it doesn't turn off it means that the input SAFETY EDGE is on stand-by or deactivated